Packing 6100
Material: thermally extended graphite without additives.
Purpose: perfectly suitable for sealing of pumps and reinforcement. Intended use: used in power stations, chemical industry, heating stations, boiler rooms. Also suitable for use in places where inert gases do not reach 1000 °C.
Maximum pressure:
- centrifugal pump: 20 bar
- plunger pump: 100 bar
- reinforcement: 250 bar
Min temperature: -220 °C
Max temperature: 450 °C (gas) and 550 °C (steam)
Speed:
- centrifugal pump: 10 m/s
- plunger pump: 1.5 m/s
pH: 0 - 14
Square section: 4 - 40 mm